Junction boxes for safe atmospheres

We supply a large range of junction boxes for installation in safe areas that can be used for connection to the power supply and for carrying out parallel circuits and derivations.

These boxes come in either light alloy or polyester reinforced with glass fibre and they are ideal for installation in safe atmospheres with IP66 protection or higher.

Custom designs are also available, including models in stainless steel, in order to satisfy the needs of any client.

 

Model Code Cable type Size in mm No. of terminals Terminal size Applications
JB2+1 CQ9052 self-regulating or constant wattage 140x115x60 4+T 4mmq connecting 1 or 2 cables to the power supply or T-junctions of 3 cables
JB3+1 CQ9057 self-regulating or constant wattage 140x115x60 6+T 4mmq connecting 3 cables to the power supply or to create X junctions with 4 cables
JB4+1 CQ9070 self-regulating or constant wattage 166x142x64 8+T 4mmq switching of up to 4 cables and power supply 3 x 4mm2
JB5+1 CQ9071 self-regulating or constant wattage 166x142x64 10+T 4mmq switching of up to 5 cables and power supply 3 x 4mm2
JB6+1 CQ9072 self-regulating or constant wattage 192x168x80 12+T 4mmq switching of up to 6 cables and power supply 3 x 4mm2
CASCOLSER CQ9095 mineral- or PTFE- insulated cables 166x142x64 2+T 6mmq power supply for mineral- or PTFE- insulated circuit
CASSAL3FASI/ST CQ9058 mineral- or PTFE- insulated cables 166x142x64 3+T 6mmq three-phase power supply for three mineral-insulated circuits or  PTFE-circuits at the beginning of the line
CASSGIUNZ3FAS/ST CQ9059 mineral- or PTFE- insulated cables 166x142x64 3+T 6mmq series power supply for mineral- or PTFE-insulated circuits
CASSCOL STELLA3FAS/ST CQ9060 mineral- or PTFE- insulated cables 166x142x64 3+T 6mmq star junction for three mineral- or PTFE- insulated circuits
MEASURING BOX CQ6001 PT100 140x115x60 4+T 4mmq connecting PT100 to cable transmitting to control room
JB/DESTU/ST CQ9019 self-regulating or constant wattage 166x142x64 4+T 4mmq connection of 1 or 2 cables to the power supply with support for fixing to piping
END/LAMP CQ9027 any type 166x142x64 2+T 4mmq light signaling the correct functioning of the heating circuit at the end of the line
JB/3F CQ3095 any type 253x217x93 10+4T 6mmq connection of three monophase circuits with three-phase power supply
CAS/TERM CQ9201 any type 166x142x64 4+T 4mmq power supply and control of one circuit with support and thermostat