We supply a large range of junction boxes for installation in safe areas that can be used for connection to the power supply and for carrying out parallel circuits and derivations.
These boxes come in either light alloy or polyester reinforced with glass fibre and they are ideal for installation in safe atmospheres with IP66 protection or higher.
Custom designs are also available, including models in stainless steel, in order to satisfy the needs of any client.
Model | Code | Cable type | Size in mm | No. of terminals | Terminal size | Applications |
---|---|---|---|---|---|---|
JB2+1 | CQ9052 | self-regulating or constant wattage | 140x115x60 | 4+T | 4mmq | connecting 1 or 2 cables to the power supply or T-junctions of 3 cables |
JB3+1 | CQ9057 | self-regulating or constant wattage | 140x115x60 | 6+T | 4mmq | connecting 3 cables to the power supply or to create X junctions with 4 cables |
JB4+1 | CQ9070 | self-regulating or constant wattage | 166x142x64 | 8+T | 4mmq | switching of up to 4 cables and power supply 3 x 4mm2 |
JB5+1 | CQ9071 | self-regulating or constant wattage | 166x142x64 | 10+T | 4mmq | switching of up to 5 cables and power supply 3 x 4mm2 |
JB6+1 | CQ9072 | self-regulating or constant wattage | 192x168x80 | 12+T | 4mmq | switching of up to 6 cables and power supply 3 x 4mm2 |
CASCOLSER | CQ9095 | mineral- or PTFE- insulated cables | 166x142x64 | 2+T | 6mmq | power supply for mineral- or PTFE- insulated circuit |
CASSAL3FASI/ST | CQ9058 | mineral- or PTFE- insulated cables | 166x142x64 | 3+T | 6mmq | three-phase power supply for three mineral-insulated circuits or PTFE-circuits at the beginning of the line |
CASSGIUNZ3FAS/ST | CQ9059 | mineral- or PTFE- insulated cables | 166x142x64 | 3+T | 6mmq | series power supply for mineral- or PTFE-insulated circuits |
CASSCOL STELLA3FAS/ST | CQ9060 | mineral- or PTFE- insulated cables | 166x142x64 | 3+T | 6mmq | star junction for three mineral- or PTFE- insulated circuits |
MEASURING BOX | CQ6001 | PT100 | 140x115x60 | 4+T | 4mmq | connecting PT100 to cable transmitting to control room |
JB/DESTU/ST | CQ9019 | self-regulating or constant wattage | 166x142x64 | 4+T | 4mmq | connection of 1 or 2 cables to the power supply with support for fixing to piping |
END/LAMP | CQ9027 | any type | 166x142x64 | 2+T | 4mmq | light signaling the correct functioning of the heating circuit at the end of the line |
JB/3F | CQ3095 | any type | 253x217x93 | 10+4T | 6mmq | connection of three monophase circuits with three-phase power supply |
CAS/TERM | CQ9201 | any type | 166x142x64 | 4+T | 4mmq | power supply and control of one circuit with support and thermostat |